Home
Products
Support
About TOA
For the Press
Contact Info



New Products

Training

Amplifiers &
Mixer/Amplifiers


Modules

Speakers

Network Audio

Mixers

Digital Signal Processors

Wired & Wireless Microphones

Conference Systems

Digital Message Repeaters

Megaphones

AM/FM Tuner

Program Timer

Impedance Meter


CCTV/Video Surveillance

Intercom Systems

Alphanumeric

How To Buy

Search TOA

Discontinued Products

Installation Profiles

Repair Contacts

Site Map



N-8000 Series
IP Network Intercom Systems

Award Winner!
2006 N
SCA Innovations in Technology
Security/Fire/Life Safety Category

How to Buy

The newly expanded N-8000 Series IP Network Intercom offers flexible communications for up to 3,072 stations on existing corporate local and wide area data networks. Built on TOA’s proven NX-100 network audio technology, the new IP Intercom products occupy minimal network bandwidth (130 kbps maximum) for station-to-station calls and can be controlled and monitored through software or web browser. Programmable system functions include 192 paging zones, time-based call forwarding and scan monitoring.

The backbone of the new system is the compact N-8000EX Exchange which supports 16 stations and occupies only one rack space. Features include a 10/100BaseT port for connection to standard network hardware and two paging audio outputs. Larger systems can be easily configured with up to 192 exchanges and 3,072 stations. The economy N-8010EX IP Intercom Exchange, featuring one speech link, is available as a lower-cost alternative to the four-link N-8000EX IP Intercom Exchange. The N-8000MI Multi-Interface Unit features telephone interface, BGM input, paging outputs, control signaling plus functions as an interface to legacy TOA EXES intercom systems.  Three new station exchanges have now been introduced, further expanding the system’s capabilities. The N-8000RS & N-8010RS IP Exchanges are designed to allow up to (16) VS-900 & IC-100 (RS) 2-wire substations to operate over IP. In addition, the N-8400RS Exchange uses a new line of 4-wire substations. These allow easy retrofit and upgrade of existing 2 & 4-wire systems. The new RS-140 call button panel operates on the new 2-wire exchanges but is designed to work with a 25V PA speaker in classroom applications.

Two-wire stations include The N-8000MS Multifunctional Master Station, equipped with a 32 character alphanumeric LCD display, handset and speed dial functions; the N-8010MS Standard Master Station with keypad and handset; the N-8020MS Industrial Master Station, built to withstand severe environmental conditions; and the N-8011MS Hands-Free Master Station offering hands-free simultaneous two-way (duplex) communication via an innovative ambient noise sensing function. Other two-wire stations include the N-8030MS Flush-Mount Hands-free Master Station, N-8040DS Indoor Sub-station and Q-N-8040WP Outdoor  Sub-station. For custom station applications, TOA offers the N-8031SB Hands-free Master Station Board Unit and the N-8050SB Hands-free Substation Board Unit. Station line monitoring is also available via software, web browser or station display.

Ethernet stations include the N-8500MS IP Multi-function Master Station, which has a built-in Ethernet connection for direct network connection, a 32 character alphanumeric LCD display, and handset and speed dial functions. The new N-8510MS IP Master Station provides the same functionality as the 2-wire N-8010MS. The N-8540DS IP Indoor Sub-station also connects directly to the network and includes a vandal-resistant call-switch and control output for door release. A weather-resistant version is also available, model Q-N-8540WP IP Outdoor Sub-station.

A new lineup of optional IP interfaces allows expanded system operations. These include: the N-8000AL Analog Phone Interface, which allows any standard analog phone to be used as a master station. The N-8000AF Audio Interface provides audio signal connections to paging amps, playback sources, recording devices and schedule clocks. It also incorporates a built-in bell scheduler and tone library for classroom change signals. Up to 16 different schedules of 64 events each may be programmed. The N-8000CO Outside Line Interface provides access to an outside telephone line for dial-in calling, paging and control, as well as outbound forwarding of calls made to master stations. Lastly, the N-8000DI Direct Interface provides contact ins & Outs for control of paging amps, door/gate access, CCTV camera call-up & LED status panels. It may accessed by standard controls or dialing commands from any master station on the network.

Also see the NX-100 Network Audio.



Brochure NEW!
(PDF, 600kb)

Spec. Sheet
(PDF, 1.2Mb)

Manual
(PDF, 6Mb)
Estimate Worksheet (PDF, 61 kb)
A&E Spec
(PDF, 168kb)
N-8000 CAD
(ZIP, 2737.23KB)
N-8000 Firmware

(ZIP, 4218.46KB)
N-8000 Applications Diagrams
(ZIP, 331.93KB)
Application Note for N-8000RS
(PDF, 87.26KB)


Software v2.02 NEW! (ZIP, 5746.30KB)
Note: When using software version 2.02, all N-8000 devices on the network must have firmware version 2.0 or higher. Instructions for updating the firmware are located in the N-8000 system manual under: “System Settings Using the Browser: System Management: Updating Firmware.”

Software v.1.41
For customers continuing to use original N-8000 products only and who do not require any new features or functionality, you may update the firmware in your components to v1.41.  This includes the following N-8000 models: N-8000EX, N-8010EX, N-8000MI, N-8500MS, N-8540DS & Q-8540WP. Please note- ALL system components need to be updated to the same version firmware to ensure reliable operation. The firmware for your product(s) can be found on the TOA Data Library by clicking on the following link: http://www.toa-products.com/international/.  Just enter the model number and follow the appropriate link (for U.S. models please use the “CU” version download)”. Then click on the Software (firmware) link to download.”

Note: Components with 1.41 or earlier firmware will not work with GUI software v2.00 or later.
 


FEATURES

  • Scalable network communications for up to 3,072 stations over data networks (LAN/WAN)
  • Flexible configuration options for existing cabling and network infrastructure
    Station Options:
    • IP Stations with Ethernet port connect directly to the network (up to 192 stations)
    • Connect up to sixteen two-wire stations to compact Network Exchange (up to 192 exchanges for up to  3,072 stations)
  • Occupies minimal network bandwidth — 130 kbps max. (station to station call)
  • Hands-free full-duplex conversation (Not including N-8540DS or Q-N8540WP which offer Half-Duplex conversation)
  • Control and monitor through software and web browser
  • Versatile features including 192 zone paging, time-based call forwarding and scan monitoring

SYSTEM EXCHANGES
(for two-wire stations)

N-8000EX
IP Intercom Exchange

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 192 max.)
  • Sixteen (16) station capacity
  • Stations connect to exchange via two-wire twisted pair
  • Provides 48 VDC to each station
  • Speech links: 4 internal / 8 external
  • Two (2) audio paging outputs (0 dBV)
  • Two (2) relay outputs
  • Includes rack-mount and wall-mount brackets
Manual (PDF, 346kb)
CAD (ZIP, 236.89KB)
Firmware v2.10  (N-8000EX) (ZIP, 663.25KB)


(Click image for large view)

N-8010EX
IP Intercom Exchange (economy)

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 192 max.)
  • Sixteen (16) station capacity
  • Stations connect to exchange via two-wire twisted pair
  • Provides 48 VDC to each station
  • Speech links: 1 internal / 2 external
  • Includes rack-mount and wall-mount brackets

Manual (PDF, 346kb)
CAD (ZIP, 236.89KB)
Firmware v2.10  (N-8000EX) (ZIP, 663.25KB)

N-8000RS NEW!
Sub Station Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (191 max - at least one node must be a master station or N-8000/8010EX exchange)
  • Up to 16 substations connectable using two-core shielded cable
  • Speech links: 2
  • 16.54" (W) x 1.74" (H) x 13.75" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000RS) (ZIP, 723.61KB)
Application Note for N-8000RS  (PDF, 87.26KB)

 

N-8010RS NEW!
Sub Station Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (191 max - at least one node must be a master station or N-8000/8010EX exchange)
  • Up to 16 substations connectable using two-core shielded cable
  • Speech links: 1
  • 16.54" (W) x 1.74" (H) x 12.81" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000RS) (ZIP, 723.61KB)
Application Note for N-8000RS  (PDF, 87.26KB)

 

N-8400RS NEW!
Sub Station Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (191 max - at least one node must be a master station or N-8000/8010EX exchange)
  • Up to 16 substations connectable using 2 sets of twisted pair cables
  • Speech links: 1
  • 16.54" (W) x 1.74" (H) x 12.81" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000RS) (ZIP, 723.61KB)

 

N-8000AL NEW!
Telephone Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (192 max.)
  • Single telephone line allowing an analog telephone to be connected
  • Allows any analog telephone to function as a master station.
  • 8.27" (W) x 1.74" (H) x 10.51" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000AL) (ZIP, 723.61KB)
 


N-8000AF NEW!
Audio Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (192 max.)
  • One MIC/LINE audio line input
  • One audio line output
  • Eight contact inputs
  • Time Synchronization input
  • Built-in timer and chime
  • 8.27" (W) x 1.74" (H) x 10.51" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000AF) (ZIP, 723.61KB)
 


N-8000CO
NEW!
C/O Interface Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (191 max - at least one node must be a master station or N-8000/8010EX exchange)
  • Analog central office line circuit allowing the stations to make and receive calls to and from the telephone line.
  • 8.27" (W) x 1.74" (H) x 10.51" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000CO) (ZIP, 723.61KB)


 

N-8000DI NEW!
Direct Select Unit

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node (192 max.)
  • 32 contact inputs
  • 32 contact outputs
  • Provides control interface to CCTV, door access and other external systems.
  • Events may be activated by contact closures or master station dialing commands.
  • 16.54" (W) x 1.74" (H) x 10.54" (D)

Manual (PDF, 578.26KB)
Specification Sheet (PDF, 129.09KB)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8000DI) (ZIP, 723.61KB)

 

N-8000MI
Multi-Interface (BGM, TEL, EXES, Control I/O)

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 192 max.)
  • Audio Inputs for BGM, External Tone or Paging
    • Two audio line inputs (0 dBV) with two trigger inputs
    • Two audio line outputs (0 dBV) with two relay outputs
  • Contact Bridge
  • Sixteen contact inputs
  • Sixteen relay outputs
  • Telephone Interface (E&M type), two channels
  • Interface for connecting to legacy EXES-6000 systems (Q-TI-600 also required)
  • Includes rack-mount and wall-mount brackets
Manual (PDF, 253kb)
CAD (ZIP, 314.25KB)
Firmware v2.10  (N-8000MI) (ZIP, 553.70KB)


(Click image for large view)

 

Q-TI-600
Tie-line Interface for EXES-6000 to N-8000

  • Provides two tie-line links for connection between legacy EXES-6000 systems (CP-66 version) and N-8000 systems
  • Requires two available open EXES station ports
  • Interface for connecting to legacy EXES-6000 systems (N-8000MI also required)
  • Includes rack-mount brackets

Specification Sheet (PDF, 64kb)


IP STATIONS
(connect directly to network)

N-8500MS
Multifunction IP Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station using the handset operation
  • Half-Duplex (aka: Simplex) communication is supported by this station using the Hands-Free operation
  • Connects directly to network (10/100Base TX)
  • Occupies one network node ( 80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Two RJ-45 network connectors (one for network, one for PC)
  • Alphanumeric LCD display (32 character)
  • Handset or hands-free duplex communication
  • Eight user-programmable speed dial keys
  • Headset terminal
  • External speaker terminal (0.6 W / 8 ohms)
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 139kb)
CAD (ZIP, 235.68KB)
Firmware v2.10  (N-8500MS) (ZIP, 832.42KB)

N-8510MS NEW!
IP Standard Master Station

  • Handset duplex communication
  • Connects directly to network (10/100Base TX)
  • Occupies one network node (192 max)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Two RJ-45 network connectors (one for network, one for PC)
  • Contact input terminal
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)
CAD (ZIP, 112.66KB)
Firmware v2.10  (N-8500MS) (ZIP, 832.42KB)
 

N-8540DS
Indoor IP Substation

  • Half-Duplex (aka: Simplex) communication is supported by this station
  • Connects directly to network (10/100Base TX)
  • Occupies one network node (80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A

Manual (PDF, 60kb)
CAD (ZIP, 235.68KB)
Firmware v2.10  (N-8500MS) (ZIP, 832.42KB)

Q-N8540WP
Outdoor IP Substation

  • Half-Duplex (aka: Simplex) communication is supported by this station
  • Connects directly to network (10/100Base TX)
  • Occupies one network node (80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A

Specification Sheet (PDF, 60kb)
Manual (PDF, 60kb)
Firmware v2.10  (N-8500MS) (ZIP, 832.42KB)


TWO-WIRE STATIONS
(connect to N-8000EX or N-8010EX Network Exchange)

N-8000MS
Multifunction Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Alphanumeric LCD display (32 character)
  • Handset or hands-free duplex communication
  • Eight user-programmable speed dial keys
  • Headset terminal
  • External speaker terminal (0.6 W / 8 ohms)
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)
CAD (ZIP, 112.66KB)

N-8010MS
Standard Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Handset or hands-free duplex communication
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)

 

N-8011MS
Handsfree Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station (handset mode only)
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Optional wall-mount bracket, model YC-290

Manual (PDF, 91kb)
CAD (ZIP, 112.66KB)

 

N-8020MS
Industrial Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station
  • Heavy duty dustproof and waterproof construction (IP54 rating)
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Handset or hands-free duplex communication
  • External speaker terminal (0.6 W / 8 ohms)
  • Control output
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)
CAD (ZIP, 112.66KB)

 

N-8031MS
Panel-Mount Master Station

  • Full-Duplex (aka: Duplex) communication is supported by this station (handset mode only)
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • External dial inputs (7, 8, 9 and C keys)
  • Optional Handset, model RS-191
  • Optional flush-mount back-box, model YC-241
  • Optional surface-mount back-box, model YC-251
  • Also available as PCB assy., model N-8031SB

Manual (PDF, 196kb)
CAD (ZIP, 112.66KB)

 

N-8050DS
Indoor Substation

  • Half-Duplex (aka: Duplex) communication is supported by this station
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A
  • Also available as PCB assy., model N-8050SB

Manual (PDF, 74kb)
CAD (ZIP, 112.66KB)

 

Q-N8050WP
Outdoor Substation

  • Half-Duplex (aka: Duplex) communication is supported by this station
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A
  • Also available as PCB assy., model N-8050SB

Specification Sheet (PDF, 60kb)
Manual (PDF, 60kb)

RS-150

Economy Indoor Remote Sub-Station

  • Provides half-duplex communication.

  • Hairline brushed stainless steel faceplate, #14 Gauge.

  • Connects to N-8000RS/N-8010RS.

  • May be programmed to communicate with a single master station.

  • Mounts in two-gang, 2" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (16) sixteen RS-1XO Remote Stations can be used per N-8000RS/N-8010RS exchange.

Installation Manual (PDF, 321.11KB)
Instruction Manual (PDF, 47.39KB)
Specification Sheet  (PDF, 138kb)

CAD (ZIP, 112.66KB)
 

RS-160

Indoor Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate, #11 Gauge.

  • Vandal resistant call button and speaker plate.

  • May be programmed to communicate with a single master station.

  • Connects to N-8000RS/N-8010RS.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (16) sixteen RS-1XO Remote Stations can be used per N-8000RS/N-8010RS exchange.

Installation Manual (PDF, 321.11KB)
Instruction Manual (PDF, 47.39KB)
Specification Sheet  (PDF, 138kb)

CAD (ZIP, 112.66KB)
 

RS-170

Outdoor Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate, #11 Gauge.

  • Vandal resistant call button and speaker plate.

  • May be programmed to communicate with a single master station.

  • Weather resistant conformal printed circuit board coating.

  • Connects to N-8000RS/N-8010RS.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (16) sixteen RS-1XO Remote Stations can be used per N-8000RS/N-8010RS exchange.

Installation Manual (PDF, 321.11KB)
Instruction Manual (PDF, 47.39KB)
Specification Sheet  (PDF, 138kb)

CAD (ZIP, 112.66KB)
 

RS-180

Outdoor Panic Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate, #11 Gauge.

  • Vandal resistant call button and speaker plate.

  • May be programmed to communicate with a single master station.

  • Red Call Assurance LED for ADA-compliance.

  • Labeling area for ADA-compliant message.

  • Control output - open collector type for external relay control.

    • Open collector circuit is activated when the "Call" button is pressed and stays active until the call is completed.

    • Open collector circuit is typically used to trigger a strobe light at the remote station location to indicate the station is in use. (Strobe light and relay supplied by other vendors.)

    • Open collector circuit is not remote controllable from other devices.

  • Weather resistant conformal printed circuit board coating.

  • Connects to N-8000RS/N-8010RS.
  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (16) sixteen RS-1XO Remote Stations can be used per N-8000RS/N-8010RS exchange.

Installation Manual (PDF, 321.11KB)
Instruction Manual (PDF, 47.39KB)
Specification Sheet  (PDF, 138kb)

CAD (ZIP, 112.66KB)
 

 

RS-140 NEW!

Switch Panel

 

  • Call button and privacy button with LED Indicators
  • Supports two-way (half-duplex) communication
  • Prevents incoming calls, pages & scans by pushing the privacy switch
  • Private, handset conversation is available using the RS-141
  • Connects to N-8000RS/8010RS using twisted two-core, shielded cable
     

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138kb)
CAD
(DWG, 84.85KB)

 

 

RS-141 NEW!

Optional Handset

  • Two-way, half-duplex communication using any 25V wall/ceiling speaker

  • Prevents incoming calls by pushing a privacy switch

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138KB)
CAD
(DWG, 84.85KB)

 

 

 

 

RS-450 NEW!

Substation

  • Provides half-duplex communication

  • Hairline brushed stainless steel faceplate

  • Built-in electret condenser microphone

  • Connects to N-8400RS using two twisted pair cable

  • Indoor type

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138kb)
CAD
(DWG, 84.85KB)

 

 

RS-460 NEW!

Substation

  • Provides half-duplex communication

  • Heavy-duty brushed stainless steel faceplate

  • Vandal resistant call button and speaker plate

  • Built-in electret condenser microphone

  • Connects to N-8400RS using two twisted pair cable

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138KB)
CAD
(DWG, 84.85KB)

 

 

RS-470 NEW!

Substation

  • Provides half-duplex communication

  • Dustproof and waterproof construction (IP54 rating)

  • Heavy-duty brushed stainless steel faceplate

  • Vandal resistant call button

  • Weather resistant conformal printed circuit board coating

  • Built-in electret condenser microphone

  • Connects to N-8400RS using two twisted pair cable

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138KB)
CAD
(DWG, 84.85KB)

 

 

RS-480 NEW!

Substation

  • Provides half-duplex communication

  • Dustproof and waterproof construction (IP54 rating)

  • Heavy-duty brushed stainless steel faceplate

  • Red vandal resistant call button

  • Control output - open collector type for external relay control

  • Weather resistant conformal printed circuit board coating

  • Built-in electret condenser microphone

  • Connects to N-8400RS using two twisted pair cable

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138KB)
CAD
(DWG, 84.85KB)

 

 

RS-481 NEW!

Optional Handset

  • Indoor handset used with RS-480 Substation

  • Overrides speaker connected to RS-140/RS-480 call panel and allows private conversation.

Manual (PDF, 436.63KB)

Specification Sheet  (PDF, 138KB)
CAD
(DWG, 84.85KB)

 

 


CUSTOM TWO-WIRE STATION ASSEMBLIES
(connect to N-8000EX or N-8010EX Network Exchange)

N-8031SB
Panel-Mount Master Station PCB

  • Full-Duplex (aka: Duplex) communication is supported by this station
  • N-8031 PCB for custom station applications
  • Speaker and microphone included
  • External dial inputs (7, 8, 9 and C keys) plus switch matrix connection
  • LED Status Indicator output
  • Optional Handset, model RS-191

Manual (PDF, 88kb)
CAD (ZIP, 112.66KB)

N-8050SB
 Substation PCB

  • Full-Duplex (aka: Duplex) communication is supported by this station
  • N-8050DS PCB for custom station applications
  • Speaker and microphone included
  • Control output (open collector)
  • Call switch input
  • LED Status Indicator output

Manual (PDF, 51kb)
CAD (ZIP, 112.66KB)


Google
Search WWW Search toaelectronics.com


HOME | PRODUCTS | CUSTOMER SUPPORT | ABOUT TOA NEWS | CONTACT US
SITE MAP | CAREERS
  TOA Electronics, Inc., 1350 Bayshore Highway, Suite 270 Burlingame, CA 94010
TEL: (650) 452-1200 (800) 733-7088