Shielded Twisted Pair Stations

Shielded Twisted Pair Stations

Switch Panel

Switch Panel

RS-140

The RS-140 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides Call (Red) and Privacy (white) buttons.  The call button can be programmed to report to any master station based on job specification.  Additionally both buttons have individual LED indicators to show when the button is active.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box.  The optional RS-141 handset for private calling, or a 25V/1W speaker such as the PC-580RU for room announcement applications, can be connected to the call panel station.


Optional Handset

Optional Handset

RS-141

The RS-141 is the handset option for the RS-140, RS-142, RS-143 and RS-144 call panel substations. It provides for automatic call-in when the handset is lifted from its cradle.  The volume control provides an adjustment range of 6dB for local level control.  Wall mounting is achieved using a standard US 2-gang flush or wall mount box.


PCB kit version of RS-144 dual call button panel

PCB kit version of RS-144 dual call button panel

RS-142

The RS-142 is the circuit board version of the popular RS-144 call panel substation for installation into custom designed switch enclosures.  It features the same dual button call panel station functionality and is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides Emergency and Normal button operation that can be individually programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box.  The optional RS-141 handset can be connected to the call panel station for private calling.

Single call button panel switch

Single call button panel switch

RS-143

The RS-143 single button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides a single red call button.  The call button can be programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box.  The optional RS-141 handset for private calling, or a 25V/1W speaker such as the PC-580RU for room announcement applications, can be connected to the call panel station.


Dual call button panel switch

Dual call button panel switch

RS-144

The RS-144 dual button call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides Emergency (Red) and Normal (white) buttons that can be individually programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US single gang flush or wall mount box.  The optional RS-141 handset for private calling, or a 25V/1W speaker such as the PC-580RU for room announcement applications, can be connected to the call panel station.

Economy Indoor Remote Sub-Station

Economy Indoor Remote Sub-Station

RS-150

The RS-150 single button indoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  The 4cm (1.57in) speaker provides clear audio and the single black call button allows for simple call-in operation.  The call button can be programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US dual gang flush or wall mount box.

Indoor Vandal Resistant Remote Sub-Station

Indoor Vandal Resistant Remote Sub-Station

RS-160

The RS-160 vandal resistant single button indoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides a 4cm (1.57in) speaker for clear audio and a single vandal resistant metal call button with button bezel, allowing for simple call-in operation.  Additionally the substation’s front faceplate is made from thick 11 gauge stainless steel stock for added durability.  The call button can be programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US dual gang flush or wall mount box.

Outdoor Vandal Resistant Remote Sub-Station

Outdoor Vandal Resistant Remote Sub-Station

RS-170

The RS-170 vandal resistant single button outdoor call panel substation is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides a 4cm (1.57in) speaker for clear audio and a single vandal resistant metal call button, with button bezel, allowing for simple call-in operation.  Additionally the substation’s front faceplate is made from thick 11 gauge stainless steel stock for added durability and the circuit boards have been weather treated for moisture exposed installations.  The call button can be programmed to report to any master station based on job specification.  It requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US dual gang flush or wall mount box.

Outdoor Panic Vandal Resistant Remote Sub-Station

Outdoor Panic Vandal Resistant Remote Sub-Station

RS-180

The RS-180 panic vandal resistant single button outdoor call panel substation is ADA compliant and is designed to be used with the N-8000RS or N-8010RS substation interfaces.  It provides a 4cm (1.57in) speaker for clear audio and a single vandal resistant red anodized metal call button, with button bezel, allowing for simple call-in operation.  The call button can be programmed to report to any master station based on job specification.  Additionally the substation’s front faceplate is made from thick 11 gauge stainless steel stock for added durability and the circuit boards have been weather treated for moisture exposed installations.  Visual call-in progress feedback is achieved with a red LED above the call switch.  An open collector trigger is provided for local triggering by the call-in button for devices such as a strobe light or other indicator while a call is in progress.  The substation requires 3-conductor shielded twisted pair (STP) wiring and mounts in a standard US dual gang flush or wall mount box.